Suggestions for handling the deviation of pre embedded parts in Shibo's solution
2025-05-19

1. The position of the embedded parts on the flat plate deviates from the design position

When there is a deviation in the embedded parts, the method of increasing (or lengthening) the embedded anchor plate can be used to remedy it.

Construction of pre embedded parts for building curtain walls and related issues

Correction of offset of embedded parts by welding and anchor bolt patches

Construction of pre embedded parts for building curtain walls and related issues

Extend the anchor plate and fix it with chemical bolts


2. The embedded parts are skewed

When there is a deviation, the angle of the adapter can be adjusted to accommodate the deviation caused by the installation of the adapter, or a new anchor plate can be used as a substitute.

Construction of pre embedded parts for building curtain walls and related issues

Change the angle of the adapter to adapt to the deviation of the embedded parts

Construction of pre embedded parts for building curtain walls and related issues

Replace the original groove type embedded parts with new anchor plates


3. Hollow appears under the pre embedded anchor plate

When voids appear under the embedded parts, they should be filled with cement mortar and compacted.

Construction of pre embedded parts for building curtain walls and related issues


4. Measures to prevent welding heat effects on chemical anchoring components of rear embedded parts

Construction of pre embedded parts for building curtain walls and related issues

Add adapter plates to the original embedded parts to reduce the impact of welding temperature